Add to Cart
Temperature is the key factor during beverage production and it determines the flavor of beverages.
What we can do for your beverage water chillers?
(1).Ultra low temperature design
(2).Precise temperature control
(3).Custom cooling capacity / voltage
(4).Independent design & easy installation
(5).These fermented beverages include craft beer breweries, distilleries, wineries, cider, we can provide you with the right chiller according to your requirement on cooling capacity.
Why the craft beverages processing will need water chillers?
Our engineers understand your fermented craft process, with their experiences they can help to choose the right chiller for your specific needs to minimize costs. For example, several factors must be considered when choose a water chillers: the temperature your want during process, the brew house capacity, the quantity and volume of fermentation tanks as well as the quantity and volume for the brite tanks.
Warranty | 1 Year |
Application | Brewing,Food And Beverage, Chemical, Pharmaceutical, Industrial |
Temperature | -5℃ ~ Room Temperature |
Total Input Power | 1.42 Kw~49.65 |
Refrigeration | R22/ R407C/R410a |
Condition | 100% NEW |
Temperature Outlet Range | -10 Degree C~+35 Degree C |
Evaporator | Shell And Tube |
Condenser Type | Shell And Tube/Tank With Coil |
Water Flow | 1.17 M3/h~19.34 @-5 Degree C Outlet |
Technical Details of Industrial Grade Glycol Chilling System for -5 C Temperature Outlet Range For Beverage Process Line
Model | DK-3C | DK-5C | DK-6C | DK-8C(D) | DK-10C(D) | DK-12C(D) | DK-15C(D) | DK-20C(D) | DK-25C(D) | DK-30C(D) | DK-40C(F) | DK-50C(F) | |
Cooling capacity | At 0℃ Outlet (Kw) | 6.8 | 10.5 | 12.2 | 16.2 | 22.8 | 24.8 | 33.4 | 44.2 | 50.5 | 66.9 | 87.7 | 110.6 |
At -5℃ Outlet (Kw) | 5.7 | 8.9 | 10.3 | 13.8 | 19.3 | 21.0 | 28.4 | 37.6 | 43 | 56.8 | 74.5 | 94 | |
Power | Kw | 3.45 | 5.45 | 6.31 | 8.22 | 10.54 | 12.33 | 15.84 | 20.51 | 23.52 | 31.81 | 40.18 | 47.92 |
Power Supply | 3PH-380V-50Hz | ||||||||||||
Refrigerant | Type | R22/R407C | |||||||||||
Control | Thermostatic expansion valve | ||||||||||||
Compressor | Type | Hermetic scroll type | |||||||||||
Power(Kw) | 2.84 | 4.36 | 5.2 | 3.5*2 | 4.4*2 | 5.2*2 | 6*2 | 8.7*2 | 10.2*2 | 8.7*3 | 8.7*4 | 10.2*4 | |
Evapoirator | Type | SS Tank with coil or Shell and tube Or Plate Heat Exchanger | |||||||||||
At 0℃ Outlet Water Flow(m3/h) | 1.29 | 1.99 | 2.31 | 3.07 | 4.32 | 4.70 | 6.33 | 8.37 | 9.57 | 12.68 | 16.62 | 20.96 | |
At -5℃ Outlet Water Flow(m3/h) | 1.17 | 1.83 | 2.12 | 2.84 | 3.97 | 4.32 | 5.84 | 7.73 | 8.85 | 11.68 | 15.33 | 19.34 | |
Capacity(L) | 50 | 70 | 70 | 120 | 200 | 200 | 270 | 350 | 350 | 450 | 580 | 580 | |
Inlet/Outlet | DN20 | DN20 | DN32 | DN32 | DN32 | DN32 | DN40 | DN40 | DN40 | DN65 | DN65 | DN80 | |
Condenser | Type | High efficiency hydrophilic aluminum foll finned type | |||||||||||
Fan Power(Kw) | 0.25 | 0.52 | 0.52 | 0.24*2 | 0.52*2 | 0.52*2 | 0.55*2 | 0.75*2 | 0.75*2 | 0.75*2 | 1.5*2 | 0.75*4 | |
Pump | Type | Centrigual water pump | |||||||||||
Power(Kw) | 0.37 | 0.55 | 0.55 | 0.55 | 0.55 | 0.55 | 1.5 | 1.5 | 1.5 | 2.2 | 2.2 | 2.2 | |
Lift(m) | 24 | 25 | 24 | 20 | 20 | 20 | 20 | 20 | 20 | 21 | 20 | 19 | |
Protection System | Compressor overheat protection, high/low pressure protection, phase missing/sequence protection, flow rate protection, anti-frozen protection. | ||||||||||||
Dimension | L (mm) | 700 | 900 | 900 | 950 | 1560 | 1560 | 1800 | 2100 | 2100 | 2200 | 2500 | 2000 |
W (mm) | 550 | 850 | 850 | 900 | 850 | 850 | 1000 | 1000 | 1000 | 1160 | 1460 | 2000 | |
H (mm) | 1000 | 1800 | 1800 | 1900 | 1500 | 1500 | 1600 | 1700 | 1700 | 1900 | 2000 | 1750 | |
Weight | Kg | 150 | 200 | 230 | 310 | 450 | 500 | 750 | 850 | 900 | 1150 | 1350 | 1600 |
Where is water chillers normally used in different drinkd processing?
Craft beer brewery – wort cooling, control of fermentation temperature, cooling vessels/tun, pre-packaging cooling, cooling of storage
Wineries – cooling of fermentation process, room cooling etc.
Cider – fermentation temperature control, chilling of juice, storage cooling
Distillery – cooling of fermentation process, distillation Tanks & stills etc.
Our Low Temperature Glycol Chiller product comes with comprehensive technical support and services to ensure optimal performance and longevity. Our team of experienced technicians is available to answer any questions you may have about the product, as well as to troubleshoot any issues that may arise during operation.
In addition, we offer a range of services to help you get the most out of your Low Temperature Glycol Chiller, including installation, maintenance, and repair. Our technicians are trained to provide fast and efficient service, so you can get back to work as quickly as possible.
Whether you need help with startup and commissioning, regular maintenance, or emergency repairs, our team is here to help. Contact us today to learn more about our technical support and services for the Low Temperature Glycol Chiller product.
Product Packaging:
Shipping:
If you require a cooling equipment for your project? Darko is a top-rated enterprise that will be standing first to meet your cooling needs by offering a reliable working cooling equipment.
There is no need to waste your time searching when the best option is already available. Make sure to fix a meeting with our sales staff for your deep satisfaction then confirm your order.
In order to save your time, you can send us the follows information when you contact with us:
1. What's the cooling capacity need? can use Kw, tons, or Kcal/h.
2. If you can't make sure the capacity, may I know what's the water flow in your system?
3. What's the inlet and outlet temperature need?
So that we can calculate and make and suitable chiller proposal for you.
Jinan Darko Machinery Co.,Ltd
Contact: Miss Jamie Zhang
Mobile: +86-15053152757 (Whatsapp/Weichat)
Email: jamie@darkochiller.com